MODE STBY: CMSG ELELLNNN 5,0,WS,2
QMSG QMSG error: notExecutableCmd
INIT restablish TCP/IP connection with the i-th PS
...
MODE <elementName> STBY|OPER
POLA POLA unipolarWithRemoteCtl send set polarity aggiustare tempo di commutazione
bipolar error: notExecutableCmd
SSLP set slew rate
NOTE: the power supply must stay in STANDBY state to accept the SSLP command.
Specifications for quadrupoles ask for a setting range from 1 to 10 [A/s]
Tested on quadrupoles: the raw setting range is (10,290); lower and higher values are forced to 10 and 290.
The raw setting range for quadrupoles seems wrong: it should be (10,100). It is not clear what happens for settings between 100 and 290.
PSET load current set register
...
WARNING: se si setta un valore in polarità negativa, il readout sarà con il segno negativo e quindi la control produrrà un errore di value not reached! RESOLVED
SET2 SET2 sets the two values for the #OfCycleAtSet and #OfCyclesAtZero
SET2 <elementName> <#OfCycleAtSet>: <fakeName> <fakeName> <#OfCyclesAtZero>
WARNING: fakeName is mandatory and must be a 8 characters string. As an example, it could be a repetition of <elementName> or any 8 characters dummy string (e.g. "FAKENAME")
...