MODE STBY: CMSG ELELLNNN 5,0,WS,2


QMSG  QMSG  error: notExecutableCmd

INIT  restablish TCP/IP connection with the i-th PS

...

      MODE <elementName> STBY|OPER


POLA  POLA  unipolarWithRemoteCtl   send set polarity     aggiustare tempo di commutazione

      bipolar                 error: notExecutableCmd

SSLP  set slew rate

NOTE: the power supply must stay in STANDBY state to accept the SSLP command.
Specifications for quadrupoles ask for a setting range from 1 to 10 [A/s]
Tested on quadrupoles: the raw setting range is (10,290); lower and higher values are forced to 10 and 290.
The raw setting range for quadrupoles seems wrong: it should be (10,100). It is not clear what happens for settings between 100 and 290.


PSET  load current set register

...

WARNING: se si setta un valore in polarità negativa, il readout sarà con il segno negativo e quindi la control produrrà un errore di value not reached! RESOLVED

SET2  SET2  sets the two values for the #OfCycleAtSet and #OfCyclesAtZero

      SET2 <elementName> <#OfCycleAtSet>: <fakeName> <fakeName> <#OfCyclesAtZero>

      WARNING: fakeName is mandatory and must be a 8 characters string. As an example, it could be a repetition of <elementName> or any 8 characters dummy string (e.g. "FAKENAME")

...