This section contains all information about DAFNE Network. You

In this page you can find all network switches connection and inside section's pages you can find all port configuration.

...

Room NameRoom NumberPositionSwitch NameSwitch ModelPortConnected to
Nuova Sala Controllo BTF???


Rack 28BSWBTFCRNEWCisco 2960-X 48pSFP2

???-28B-SWFINUDAGE-GBIC9

SWBTFCR2Cisco 2960-X 48pSFP1???-???-???
SWFINUDAGECisco 3550 10gbicGBIC1??-28B-PC1-4A,4B →
CALCOLO ???
GBIC5

???-28B-SWFINUDASALA-GBIC1

GBIC6

???-28B-SWFINUDASALA-GBIC2

GBIC7

???-021HM-SWFINUDASALA2-SFP1

GBIC8

???-021HM-SWFINUDASALA2-SFP2

GBIC9

???-28B-SWBTFCRNEW-SFP2

GBIC10Connected Fiber but port offline
SWFINUDASALACisco 3550 48pGBIC1

???-28B-SWFINUDAGE-GBIC5

GBIC2???-28B-SWFINUDAGE-GBIC6
Rack 021HMSWFINUDASALA2Cisco 2960G 20p + 4sfpSFP1

???-28B-SWFINUDAGE-GBIC7

SFP2???-28B-SWFINUDAGE-GBIC8
Nuova Sala Sperimentale BTF19

...

Rack 006SWBTF

...

Cisco 3550 48p

...

...

GBIC119-006-PC1-1,2
41-028-PC1-1,2
41-028-

...

SWLAT-

...

MOD5-1
SWBTF3

...

Cisco 2960-X 48p

...

...

SFP119-006-PC1-19,20
41-028-PC4-4A,4B
41-028-

...

SWLAT-

...

MOD4-12

...

SFP219-006-PC1-17,18
41-028-PC4-3A,3B
41-028-

...

SWLAT-

...

MOD4-11








  • Sala Alimentatori Accumulatore (21)
    • Rack 018 ("5 Gradini")
      • swacc1 (2960-X 48p)
        • sfp2
          • 21-018-PC1-1A,1B
          • 19-006-PC3-7A,7B
          • 19-006-PC1-3,4
          • 41-028-PC1-3,4
          • 41-028-swlat-mod5-2

  • Sala Alimentatori Dafne - Sala Conteggio (43)
    • Rack 074
      • swalimdafne (2960-X 48p)
        • sfp1
          • 43-074-PC1-1A,1B
          • 41-028-PC3-1,2
          • 41-028-swlat-mod5-8

    • Rack 082
      • Unmanaged (HPE OfficeConnect 1420 24p)
        • p24
          • swalimdafne-45

    • Rack 078
      • Unmanaged (HPE OfficeConnect 1420 24p)
        • p24
          • swalimdafne-46

    • Rack 076
      • Unmanaged (HPE OfficeConnect 1420 24p)
        • p24
          • swalimdafne-47

    • Rack 067
      • Unmanaged (HPE OfficeConnect 1420 16p)
        • p16
          • swalimdafne-48

  • Sala Controllo DAFNE (32)
    • Rack 002
      • swctrl1 (2960 24p)
        • sfp1
          • 42-030-PC5-1A,1B
          • 41-028-PC2-13,14
          • 41-028-swlat-mod5-9
        • sfp2
          • 32-T1-swctrl2-sfp1

    • Table 1
      • swctrl2 (2960-X 48p)
        • sfp1
          • 32-002-swctrl1-sfp2

    • Rack 005
      • Unmanaged (HPE OfficeConnect 1420 24p)
        • sfp1
          • 32-005-PC2-1A,1B
          • 41-028-PC3-13,14
          • 41-028-swlat-mod5-11

  • Sala Criogenia (10)
    • Rack 000
      • swcrio (3550 48p)
        • gbic1
          • 10-000-PC1-1,2
          • 41-028-PC1-13,14
          • 41-028-swlat-mod5-5

  • Sala Dafne (11)
    • Rack 064
      • swdafne4b (2960-X 48p)
        • sfp2
          • 11-064-PC1-1A,1B
          • 11-065-PC5-1,2
          • 11-065-PC2-11,12
          • 41-028-PC2-11,12
          • 41-028-swlat-mod4-7

    • Rack 065
      • swdafne1 (2960-X 48p)
        • sfp1
          • 11-065-PC1-1,2
          • 41-028-PC1-17,18
          • 41-028-swlat-mod5-6

    • Rack 069
      • swdafne2c (2960-X 48p)
        • sfp2
          • 11-069-PC2-7A,7B
          • 11-065-PC5-13,14
          • 11-065-PC2-7,8
          • 41-028-PC2-7,8
          • 41-028-swlat-mod4-17

    • Rack 072
      • swdafne3b (2960-X 48p)
        • sfp1
          • 11-072-PC1-1A,1B
          • 11-065-PC4-1,2
          • 11-065-PC2-9,10
          • 41-028-PC2-9,10
          • 41-028-swlat-mod4-18

    • Rack SID
      • swsiddharta10G (???)
        • sfp???
          • 11-SID-swsiddharta ???

      • swsiddharta (???)
        • sfp???
          • swsiddharta10G ???
        • sfp???
          • 11-064-PC1-4A,4B
          • 11-065-PC5-7,8
          • 11-065-PC2-5,6
          • 41-028-PC2-5,6
          • 41-028-swlat-mod4-16

    • Rack BUCA_SX
      • swlumigib (???)
        • sfp???
          • 11-064-PC1-3A,3B
          • 11-065-PC5-5,6
          • 11-065-PC2-3,4
          • 41-028-PC2-3,4
          • 41-028-swlat-mod4-15

    • Rack BUCA_DX
      • swlumichaos (???)
        • sfp???
          • 11-064-PC1-2A,2B
          • 11-065-PC5-3,4
          • 11-065-PC2-1,2
          • 41-028-PC2-1,2
          • 41-028-swlat-mod4-14

    • Rack Inverpower 3
      • Unmanaged (HP procurve 2124 J4868A 24p)
        • p24
          • 11-069-swdafne2c-19

    • Rack Inverpower 9
      • Unmanaged (HP procurve 2124 J4868A 24p)
        • p24
          • 11-069-swdafne2c-20

    • Rack Inverpower 23
      • Unmanaged (HP 1410-16G J9560A 16p)
        • p16
          • 11-065-swdafne1-19

    • Rack Inverpower 28
      • Unmanaged (HP 1410-16G J9560A 16p)
        • p16
          • 11-065-swdafne1-20

  • Sala LAT (41)
    • Rack 028
      • swlat (4506-E 36sfp 48eth)
        • mod4-7
          • 41-028-PC2-11,12 → 11-064-swdafne4b-sfp2
        • mod4-8
          • 41-028-PC1-7,8 → 03-015-PC1-3,4 → 03-???-???
        • mod4-9
          • 41-028-PC1-23,24 → 42-031-swstrum1-sfp1
        • mod4-10
          • 41-028-PC2-15,16 → 42-030-swstrum2-sfp1
        • mod4-11
          • 41-028-PC4-3A,3B → 19-006-swbtf3-sfp2

        • mod4-12
          • 41-028-PC4-4A,4B → 19-006-swbtf3-sfp1
        • mod4-13 (sfp blu - LX)
          • 41-028-PC2-17,18 → 42-030-PC5-3A,3B → 42-031-PC2-7,8 → 03-015-PC1-7,8 → 03-???-swmodnew (linac)
        • mod4-14
          • 41-028-PC2-1,2 → 11-BUCA_DX-swlumichaos-sfp???
        • mod4-15
          • 41-028-PC2-3,4 → 11-BUCA_SX-swlumigib-sfp???
        • mod4-16
          • 41-028-PC2-5,6 → 11-SID-swsiddharta-sfp??? → 11-SID-swsiddharta10G-sfp???
        • mod4-17
          • 41-028-PC2-7,8 → 11-069-swdafne2c-sfp2
        • mod4-18
          • 41-028-PC2-9,10 → 11-072-swdafne3b-sfp1
        • mod5-1
          • 41-028-PC1-1,2 → 19-006-swbtf-gbic1
        • mod5-2
          • 41-028-PC1-3,4 → 21-018-swacc1-sfp2
        • mod5-3
          • 41-028-PC1-5,6 → 03-015-swmod1-gbic1
        • mod5-4
          • 41-028-PC1-9,10 → 8b-073-swmacc-gbic1
        • mod5-5
          • 41-028-PC1-13,14 → 10-000-swcrio-gbic1
        • mod5-6
          • 41-028-PC1-17,18 → 11-065-swdafne1-sfp1
        • mod5-7
          • 41-028-PC1-21,22 → 42-031-swstrum3-sfp1
        • mod5-8
          • 41-028-PC3-1,2 → 43-074-swalimdafne-sfp1
        • mod5-9
          • 41-028-PC2-13,14 → 32-002-swctrl1-sfp1 → 32-T1-swctrl2-sfp1
        • mod5-10
          • 41-028-PC4-1A,1B → 18-017-swbtfesp1-sfp2 → 18-017-swbtfesp2-gbic1
        • mod5-11
          • 41-028-PC3-13,14 → 32-005-HP-sfp1
        • mod5-12
          • 41-028-swlat2-sfp1

      • swlat2 (2960-X 48p)
        • sfp1
          • 41-028-swlat-mod5-12

  • Sala Macchine (8b)
    • Rack 073
      • swmacc (3550 24p)
        • gbic1
          • 8b-073-PC1-1,2
          • 41-028-PC1-9,10
          • 41-028-swlat-mod5-4

  • Sala Modulatori (03)
    • Rack 015
      • swmod1 (3550 24p)
        • gbic1
          • 03-015-PC1-1,2
          • 41-028-PC1-5,6
          • 41-028-swlat-mod5-3

    • Rack "Position Linac Magnet Group"
      • SWMOD2 (3550 24p)
      • SWMOD3 (2960-X 48p)

  • Sala Sperimentale BTF (18)
    • Rack 017
      • swbtfesp1 (2960-X 48p)
        • sfp1
          • 18-017-swbtfesp2-gbic1
        • sfp2
          • 18-017-PC1-1A,1B
          • 19-006-PC3-1A,1B
          • 19-006-PC1-13,14
          • 41-028-PC4-1A,1B
          • 41-028-swlat-mod5-10

      • swbtfesp2 (3550 24p)
        • gbic1
          • 18-017-swbtfesp1-sfp1

  • Sala Strumentazione (42)
    • Rack 030
      • swstrum2 (2960-X 48p)
        • sfp1
          • 42-030-PC5-2A,2B
          • 41-028-PC2-15,16
          • 41-028-swlat-mod4-10

    • Rack 031
      • swstrum1 (2960-X 48p)
        • sfp1
          • 42-031-PC2-3,4
          • 41-028-PC1-23,24
          • 41-028-swlat-mod4-9

      • swstrum3 (2960-X 48p)
        • sfp1
          • 42-031-PC2-1,2
          • 41-028-PC1-21,22
          • 41-028-swlat-mod5-7

...