Description
Main unit containing up to 8 Power Supplies of class CHN.
Static Fork
Code Block | ||
---|---|---|
| ||
#QUATT007 @HCI(S)[(I32),(DBL),HU32,DBL,DBL,DBL,DBL,DI32,DBL:2:4] MG1,QUATT007,01010001,0.1,3.0,3.0,3.0,1,11.0:12.0:13.0:14.0:21.0:22.0:23.0:24.0 @ReadOut(A)[(DBL),DBL,DBL,DBL,DBL,DBL,DBL] currRead,1.5258789E-3,0.0,0.0,100.0,0.05,0.5 voltRead,1.0,0.0,0.0,255.0,255.0,255.0 slewRead,0.002444987775,0.0,1,10.0,0.02,1.0 ADCCRead,1.0,0.0,0.0,10.0,1.0,3.0 @Settings(A)[(DBL),DBL,DBL,DBL,DBL,DBL] currSett,1.5258789E-3,0.0,0.0,100.0,0.001 slopSett,0.002444987775,0.0,1,10.0,0.02 @EXTRA(S)[DI32,DI32,DI32:2:1] 0,10,11:21 |
...
Code Block | ||
---|---|---|
| ||
{ "elemName": 0, "status": 0, "consoleName": 0, "errorMask": 0, "cmdExeStartTime": 0, "maxCmdExeTime": 0, "cmdExecution": 0, "sysFlags": { "onLine": false, "byPass": false, "remote": false, "busy": false }, "triggerArmed": false, "statusSetting": 0, "statusReadout": 0, "faults": [], "analogCORReadout": [] } |
Details
CORDyn.status = staus readout
0 = Shutted down (status not readable)
1 = Standby
2 = Operational
3,4 = Faulty (there are some interlocks on the PS)
5 = Bad (Communication error or protocol violation or incoherent information)