Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

TypeDescription
CPU type (Low-Level demon)Windows Virtual Machine
CPU name (Low-Level demon)___
Communication lines

BTF1 Moxa Line : 192.168.__190.__ 29 (Rack __) -  (SWITCH name ______ port __)

BTF1TB01 Vertical (2 Axis), TB02 Horizontal (2 Axis), TB03 Vertical (2 Axis), TB04 Horizontal (2 Axis), TB05 Horizontal ((2 Axis), TGT001 (1 Axis)
BTF2TB06 Horizontal (2 Axis), TGT002 (1 Axis)

...

LanguageRequired Add ons/Plugings/Extensions/Libraries
LabVIEW 2010 (64-bit) - Windows

TML Lib (Technosoft Motion Library)

Hardware layout

Image Added


BTF line 1 scraper value

ScraperTB5-RTB5-LTB4-RTB4-LTB2-RTB2-LTB3-UTB3-DTB01-UTB01-DTGTTB001
Asse212034567891011
Molt112020202011111
mm giro1,51,51,51,51,51,511111
Linee Encoder163841638480080080080016001600160016001600
Range39,5239,0428,323,826,2528,0526,126,2525,324,1150
Max Speed1001002002002002001001005050100

BTF line 2 scraper value

ScraperTB6-RTB6-LTGTTB002
Asse242522
Molt111
mm giro1,51,51,5
Linee Encoder163841638416384
Range39,234099,57
Max Speed100100100

Hardware FrontHardware Front-end

The motors are controlled by drives called "MOTION SYSTEM INTERFACE DEVICE" assembled by "RAMTRON Computing".
The box is equipped with two Technosoft drives IDM240-5EI or IDM640-8EI , to operate 2 Stepper Motors.

...

Cabling of new line BTF Scraper system (May 2018) for one axis only.

Drivers Configuration

STEP 1:

Connect the designed scraper to the computer

STEP 2:

Select the axis number

(control if the axis number is correct by checking the bottom right corner "AxisID")

Image Added

STEP 3:

Create a new project by going: New> Close Frame Drive > IDM240-5EI CAN> 2 Phase stepper> Open Loop> Load sensor - None or Incremental

and for last select Setup 

STEP 4:

Configure the uSwitch like in the image

Image Added

STEP 5:

From the set up window start the Test Phase Connection

Image Added

After the test is ended start the Identify Resistance and Inductance then save the new values

Image Added

STEP 6:

Click drive setup to change window

Image Added

start Power supply detect and set start current 

Image Added

after start the Tune and test

Image Added

If the test fail, will be needed to adjust the response value till the test reach a positive result ( our configuration is works the best with a 1800 response value)

Image Added

STEP 7:

Once all the test and configuration is ended click the button on top of the app to export the configuration

Image Added

after a quick load press the red "X" next to the export button and save the project