Room NameRoom NumberPositionSwitch NameSwitch ModelPortConnected to
Nuova Sala Controllo BTF31a


Rack 28BSWBTFCR1Cisco 2960-X 48pSFP2

31a-28B-SWFINUDAGE-GBIC9

SWFINUDAGECisco 3550 10gbicGBIC131a-28B-PC1-4A,4B →
CALCOLO
GBIC5

31a-28B-SWFINUDASALA-GBIC1

GBIC6

31a-28B-SWFINUDASALA-GBIC2

GBIC7

31a-021HM-SWFINUDASALA2-SFP1

GBIC8

31a-021HM-SWFINUDASALA2-SFP2

GBIC9

31a-28B-SWBTFCR1-SFP2

GBIC10Connected Fiber but port offline
SWFINUDASALACisco 3550 48pGBIC1

31a-28B-SWFINUDAGE-GBIC5

GBIC231a-28B-SWFINUDAGE-GBIC6
Rack 021HMSWFINUDASALA2Cisco 2960G 20p + 4sfpSFP1

31a-28B-SWFINUDAGE-GBIC7

SFP231a-28B-SWFINUDAGE-GBIC8
Nuova Sala Sperimentale BTF19Rack 006SWBTFCisco 3550 48pGBIC119-006-PC1-1,2 →
41-028-PC1-1,2 →
41-028-SWLAT-MOD5-1
SWBTFEH22Cisco 2960-X 48pSFP119-006-PC1-19,20 →
41-028-PC4-4A,4B →
41-028-SWLAT-MOD4-12
SFP219-006-PC1-17,18 →
41-028-PC4-3A,3B →
41-028-SWLAT-MOD4-11
Sala Alimentatori Accumulatore21Rack 018SWACC1Cisco 2960-X 48pSFP221-018-PC1-1A,1B →
19-006-PC3-7A,7B →
19-006-PC1-3,4 →
41-028-PC1-3,4 →
41-028-SWLAT-MOD5-2
Sala Alimentatori Dafne (o Sala Conteggio)43Rack 074SWALIMDAFNE1Cisco 2960-X 48pSFP143-074-PC1-1A,1B →
41-028-PC3-1,2 →
41-028-SWLAT-MOD5-8
ETH4543-082-UNMANAGED-24
ETH4643-078-UNMANAGED-24
ETH4743-076-UNMANAGED-24
ETH4843-067-UNMANAGED-16
Rack 082UnmanagedHP OfficeConnect 1420 24pETH2443-074-SWALIMDAFNE1-45
Rack 078UnmanagedHP OfficeConnect 1420 24pETH2443-074-SWALIMDAFNE1-46
Rack 076UnmanagedHP OfficeConnect 1420 24pETH2443-074-SWALIMDAFNE1-47
Rack 067UnmanagedHP OfficeConnect 1420 16pETH1643-074-SWALIMDAFNE1-48
Sala Controllo DAFNE32Rack 002SWCTRL1Cisco 2960 24pSFP1

42-030-PC5-1A,1B →
41-028-PC2-13,14 →
41-028-SWLAT-MOD5-9

SFP232-T1-SWDAFNECR2-SFP1
Table 1SWDAFNECR2Cisco 2960-X 48pSFP132-002-SWCTRL1-SFP2
Rack 005UnmanagedHP OfficeConnect 1420 24pSFP132-005-PC2-1A,1B →
41-028-PC3-13,14 →
41-028-SWLAT-MOD5-11
Sala Criogenia10Rack 000SWCRIOCisco 3550 48pGBIC110-000-PC1-1,2 →
41-028-PC1-13,14 →
41-028-SWLAT-MOD5-5
Sala Dafne11Rack 064SWDAFNEH4Cisco 2960-X 48pSFP211-064-PC1-1A,1B →
11-065-PC5-1,2 →
11-065-PC2-11,12 →
41-028-PC2-11,12 →
41-028-SWLAT-MOD4-7
Rack 065SWDAFNEH1Cisco 2960-X 48pSFP111-065-PC1-1,2 →
41-028-PC1-17,18 →
41-028-SWLAT-MOD5-6
ETH1911-I23-UNMANAGED-16
ETH2011-I28-UNMANAGED-16
Rack 069SWDAFNEH2Cisco 2960-X 48pSFP211-069-PC2-7A,7B →
11-065-PC5-13,14 →
11-065-PC2-7,8 →
41-028-PC2-7,8 →
41-028-SWLAT-MOD4-17
ETH1911-I3-UNMANAGED-24
ETH2011-I9-UNMANAGED-24
Rack 072SWDAFNEH3Cisco 2960-X 48pSFP111-072-PC1-1A,1B →
11-065-PC4-1,2 →
11-065-PC2-9,10 →
41-028-PC2-9,10 →
41-028-SWLAT-MOD4-18
Rack SIDSWSIDDHARTA10G???SFP?11-SID-SWSIDDHARTA-SFP?
SWSIDDHARTA???SFP?11-SID-SWSIDDHARTA10G-SFP?
SFP?11-064-PC1-4A,4B →
11-065-PC5-7,8 →
11-065-PC2-5,6 →
41-028-PC2-5,6 →
41-028-SWLAT-MOD4-16
Rack BUCA SXSWLUMIGIB???SFP?11-064-PC1-3A,3B →
11-065-PC5-5,6 →
11-065-PC2-3,4 →
41-028-PC2-3,4 →
41-028-SWLAT-MOD4-15
Rack BUCA DXSWLUMICHAOS???SFP?11-064-PC1-2A,2B →
11-065-PC5-3,4 →
11-065-PC2-1,2 →
41-028-PC2-1,2 →
41-028-SWLAT-MOD4-14
Rack Inverpower 3UnmanagedHP Procurve 2124 J4868A 24pETH2411-069-SWDAFNEH2-19
Rack Inverpower 9UnmanagedHP Procurve 2124 J4868A 24pETH2411-069-SWDAFNEH2-20
Rack Inverpower 23UnmanagedHP 1410-16G J9560A 16pETH1611-065-SWDAFNEH1-19
Rack Inverpower 28UnmanagedHP 1410-16G J9560A 16pETH1611-065-SWDAFNEH1-20
Sala LAT41Rack 028SWLATCisco 4506-E 48p + 36sfpMOD4-741-028-PC2-11,12 →
11-065-PC2-11,12 →
11-065-PC5-1,2 →
11-064-PC1-1A,1B →
11-064-SWDAFNEH4-SFP2
MOD4-841-028-PC1-7,8 →
03-015-PC1-3,4 →
03-PLMG-SWMOD2OLD-GBIC1
MOD4-941-028-PC1-23,24 →
42-031-PC2-3,4 →
42-031-SWSTRUM1-SFP1
MOD4-1041-028-PC2-15,16 →
42-030-PC5-2A,2B →
42-030-SWSTRUM2-SFP1
MOD4-1141-028-PC4-3A,3B →
19-006-PC1-17,18 →
19-006-SWBTFEH22-SFP2
MOD4-1241-028-PC4-4A,4B →
19-006-PC1-19,20 →
19-006-SWBTFEH22-SFP1
MOD4-1341-028-PC2-17,18 →
42-030-PC5-3A,3B →
42-031-PC2-7,8 →
03-015-PC1-7,8 →
03-PLMG-SWMOD3-SFP2
MOD4-1441-028-PC2-1,2 →
11-065-PC2-1,2 →
11-065-PC5-3,4 →
11-064-PC1-2A,2B →
11-BUCA_DX-SWLUMICHAOS-SFP?
MOD4-1541-028-PC2-3,4 →
11-065-PC2-3,4 →
11-065-PC5-5,6 →
11-064-PC1-3A,3B →
11-BUCA_SX-SWLUMIGIB-SFP?
MOD4-1641-028-PC2-5,6 →
11-065-PC2-5,6 →
11-065-PC5-7,8 →
11-064-PC1-4A,4B →
11-SID-SWSIDDHARTA-SFP?
11-SID-SWSIDDHARTA10G-SFP?
MOD4-1741-028-PC2-7,8 →
11-065-PC2-7,8 →
11-065-PC5-13,14 →
11-069-PC2-7A,7B →
11-069-SWDAFNEH2-SFP2
MOD4-1841-028-PC2-9,10 →
11-065-PC2-9,10 →
11-065-PC4-1,2 →
11-072-PC1-1A,1B →
11-072-SWDAFNEH3-SFP1
MOD5-141-028-PC1-1,2 →
19-006-PC1-1,2 →
19-006-SWBTF-GBIC1
MOD5-241-028-PC1-3,4 →
19-006-PC1-3,4 →
19-006-PC3-7A,7B →
21-018-PC1-1A,1B →
21-018-SWACC1-SFP2
MOD5-341-028-PC1-5,6 →
03-015-PC1-1,2 →
03-015-SWMOD1OLD-GBIC1
MOD5-441-028-PC1-9,10 →
8b-073-PC1-1,2 →
8b-073-SWMACC-GBIC1
MOD5-541-028-PC1-13,14 →
10-000-PC1-1,2 →
10-000-SWCRIO-GBIC1
MOD5-641-028-PC1-17,18 →
11-065-PC1-1,2 →
11-065-SWDAFNEH1-SFP1
MOD5-741-028-PC1-21,22 →
42-031-PC2-1,2 →
42-031-SWSTRUM3-SFP1
MOD5-841-028-PC3-1,2 →
43-074-PC1-1A,1B →
43-074-SWALIMDAFNE1-SFP1
MOD5-941-028-PC2-13,14 →
42-030-PC5-1A,1B →
32-002-SWCTRL1-SFP1 →
32-T1-SWDAFNECR2-SFP1
MOD5-1041-028-PC4-1A,1B →
19-006-PC1-13,14 →
19-006-PC3-1A,1B →
18-017-PC1-1A,1B →
18-017-SWBTFEH11-SFP2
18-017-SWBTFESP2-GBIC1
MOD5-1141-028-PC3-13,14 →
32-005-PC2-1A,1B →
32-005-UNMANAGED-SFP1
MOD5-1241-028-SWLAT2-SFP1
SWLAT2Cisco 2960-X 48pSFP141-028-SWLAT-MOD5-12
Sala Macchine8bRack 073SWMACCCisco 3550 24pGBIC18b-073-PC1-1,2 →
41-028-PC1-9,10 →
41-028-SWLAT-MOD5-4
Sala Modulatori03Rack 015SWMOD1OLDCisco 3550 24pGBIC103-015-PC1-1,2 →
41-028-PC1-5,6 →
41-028-SWLAT-MOD5-3
Rack PLMGSWMOD2OLDCisco 3550 24pGBIC103-015-PC1-3,4 →
41-028-PC1-7,8 →
41-028-SWLAT-MOD4-8
SWMOD3Cisco 2960-X 48pSFP203-015-PC1-7,8 →
42-031-PC2-7,8 →
42-030-PC5-3A,3B →
41-028-PC2-17,18 →
41-028-SWLAT-MOD4-13
Sala Sperimentale BTF18Rack 017SWBTFEH11Cisco 2960-X 48pSFP118-017-SWBTFESP2-GBIC1
SFP218-017-PC1-1A,1B →
19-006-PC3-1A,1B →
19-006-PC1-13,14 →
41-028-PC4-1A,1B →
41-028-SWLAT-MOD5-10
SWBTFESP2Cisco 3550 24pGBIC118-017-SWBTFEH11-SFP1
Sala Strumentazione42Rack 030SWSTRUM2Cisco 2960-X 48pSFP142-030-PC5-2A,2B →
41-028-PC2-15,16 →
41-028-SWLAT-MOD4-10
Rack 031SWSTRUM1Cisco 2960-X 48pSFP142-031-PC2-3,4 →
41-028-PC1-23,24 →
41-028-SWLAT-MOD4-9
SWSTRUM3Cisco 2960-X 48pSFP142-031-PC2-1,2 →
41-028-PC1-21,22 →
41-028-SWLAT-MOD5-7
Sala Controllo SPARC (vetrina servers)6aRack ???Core 1Cisco C9500-40X-AC 48pSFP 01 (LACP)6a-???-PC?-1a,1b →
Calcolo →
ore switch calcolo





SFP 02 (LACP)

6a-???-PC?-?a,?b →
7-???-PC?-?a,?b
7-???-PC?-?a,?b →
RR-C-SWITCH-C9200-001-port?






SFP 03 (LACP)

6a-???-PC?-?a,?b →
7-???-PC?-?a,?b
7-???-PC?-?a,?b →
RR-C-SWITCH-C9200-002-port?






SFP 04 (LACP)

6a-???-PC?-?a,?b →
7-???-PC?-?a,?b
7-???-PC?-?a,?b →
STR-C-SWITCH-C9200-001-port?






SFP 04 - 12 (LACP)Reserved for LACP dual links












SFP 176a-???-PC?-1a,1b →
7-00A-PC?-1a,1b →
SWFLAME-001





SFP 186a-???-PC?-2a,2b →
56-00A-PC?-?a,?b →
56-00B-PC?-?a,?b →

SWFLAME-002





SFP 196a-???-PC?-3a,3b →
56-00A-PC?-?a,?b →
56-???-PC?-?a,?b →

SWFLAME-003





SFP 20-24...reserved for FLAME...









Rack ???Core 2Cisco C9500-40X-AC 48pSFP 01 - 12 (LACP)Same as Switch "Core 1"












SFP 13

6a-???-PC?-?a,?b →
7-???-PC?-?a,?b →
ED7-SABINA-CAMERA-PULITA






SFP 146a-???-PC?-?a,?b →
7-???-PC?-?a,?b →
ED7-PLASMA-LAB