Single Power Supplies.

Static Fork


Code Block
languagetext
titleDBFile example
#QUATT007
@HCI(S)[(I32),(DBL),HU32,DBL,DBL,DBL,DBL,DI32,DBL:2:4]
MG1,QUATT007,01010001,0.1,3.0,3.0,3.0,1,11.0:12.0:13.0:14.0:21.0:22.0:23.0:24.0
@ReadOut(A)[(DBL),DBL,DBL,DBL,DBL,DBL,DBL]
currRead,1.5258789E-3,0.0,0.0,100.0,0.05,0.5
voltRead,1.0,0.0,0.0,255.0,255.0,255.0
slewRead,0.002444987775,0.0,1,10.0,0.02,1.0
ADCCRead,1.0,0.0,0.0,10.0,1.0,3.0
@Settings(A)[(DBL),DBL,DBL,DBL,DBL,DBL]
currSett,1.5258789E-3,0.0,0.0,100.0,0.001
slopSett,0.002444987775,0.0,1,10.0,0.02
@EXTRA(S)[DI32,DI32,DI32:2:1]


Code Block
languagetext
titleJson
{
  "MG1HCISta.ctl": {
    "recordClass": 0,
    "elemName": 0,
    "elemType": 0,
    "maxCmdExeTime#0": 0,
    "maxCmdExeTime#1": 0,
    "maxCmdExeTime#2": 0,
    "maxCmdExeTime#3": 0,
    "polaritySwitch": 0,
    "interpolCoeff": [
      []
    ]
  },
  "readOutArray": [],
  "settingArray": [],
  "MG1ExtraSta": {
    "serialChID": 0,
    "slaveAddress": 0,
    "E642PgmTable": [
      []
    ]
  }
}

Dynamic Fork

Code Block
languagetext
titleDBFile example
#QUATT007
@HCI(S)[(DBL),DI32,DI32,DI32,DI32,DI32,DI32,TF,TF,TF,TF,TF,TF,DBL,DI32,DI32,DBL,DBL,DI32,DI32,DBL,DBL,DBL,DU32:4]
QUATT007,0,000,0,0,0,0,1,0,1,0,0,0,0.0,0,0,0.0,9.9,0,0,0.0,9.9,0.0,0:0:0:0


Code Block
languagetext
titleJson
{
  "MG1HCIDyn": {
    "elemName": 0,
    "status": 0,
    "consoleName": 0,
    "errorMask": 0,
    "cmdExeStartTime": 0,
    "maxCmdExeTime": 0,
    "cmdExecution": 0,
    "sysFlags": {
      "onLine": false,
      "byPass": false,
      "remote": false,
      "busy": false
    },
    "triggerArmed": false,
    "rampOn": false,
    "currentPreSetting": 0,
    "statusSetting": 0,
    "polaritySetting": 0,
    "currentSetting": 0,
    "slewRateSetting": 0,
    "cycleMode": 0,
    "outputPolarity": 0,
    "outputCurr": 0,
    "slewRateReadout": 0,
    "outputVolt": 0,
    "faults": []
  }
}

...

0  = Shutted down (status not readable)
1  = Standby
2  = Operational
3  = Faulty (there are some interlocks on the PS)
4  = Bad (Communication error or protocol violation or incoherent information)

...

Anchor
MG1_type_descriptor
MG1_type_descriptor

Element type descriptor

Excerpt

The elemType descriptor discriminates the PS sub-class (OCEM E642, DANFYSIC SYS8X00, etc...)

@HCI(S)[(I32),(DBL),HU32,DBL,DBL,DBL,DBL,DI32,DBL:1:5]

MG1,DVRTT001,00010101,3,3.0,3.0,3.0,1,0.812713:3.660710:0.002425:-0.000008:-0.0

byte 3

PS type

(

...

*) meaningful only for E642 and EEI

byte 2

...

Polarity control

byte 1

InterfaceType

(*) meaningful only for SYS8X00, serial Modbus

byte 0

Protocol

E642 (alarm type)

0 = 1, 5A, 5B
1 = 2, 3, 4
2 = DIP/WIG
3 = TermPoleWIG

EEI

1 = Quadrupoles DC
2 = Dipoles DC
3 = Pseudo-pulsed

0 = bipolar
1 = unipolar with rem. ctl
2 = unipolar without rem. ctl

0 = SYS8000
1 = SYS8X00 uni
2 = SYS8800 bip

0 = E642 uni
1 = E642 bip
2 = E642 pulsed

0 =  Splitter(modbus)
1 = Skew(modbus)
2 = BTF_Pulsed(modbus)

0 = SYS8X00
1 = E642
2 = Modbus
3 = Probus
4 = VSP
5 = Genesys
6 = CAENels Easy Driver
7 = Modbus TCP EEI
8 = CAENels NGPS (new UFS)

NOTE (*): byte 1 and byte 3 are decoded by the elemType2InterfaceType VI only for some PS classes:

  • byte 1 is meaningful only for SYS8X00 and serial Modbus
  • byte 3 is meaningful only for E642 and EEI
  • byte 0 and byte 2 do not depend on "protocol" and are passed through as they are.
    Be aware

...

  • that byte 1 and byte 3 can

...

  • also be used to discriminate other

...

  • types but, in that case, they have to be interpreted by

...

  • a dedicated piece of code.

00  01  01  01

| 3 | 2 | 1 | 0 |

byte 3      type 1,5A,5B

byte 2      unipolar with remote ctl

byte 1      E642 bip <--- DON'T CARE FOR OCEM

byte 0      Protocol E642

@HCI(S)[(I32),(DBL),HU32,DBL,DBL,DBL,DBL,DI32,DBL:2:4]

MG1,QUATM008,01010001,0.1,3.0,3.0,3.0,1,11.0:12.0:13.0:14.0:21.0:22.0:23.0:24.0

01  01  00  01

| 3 | 2 | 1 | 0 |

byte 3      type 2,3,4

byte 2      unipolar with remote ctl

byte 1      E642 uni <--- DON'T CARE FOR OCEM

byte 0      Protocol E642

An OCEM PS that can switch has the elemType:

XX01XX01

grep [0-9][0-9]01[0-9][0-9]01 ./DEVIL6??.DBSta

or

...

Most recent elemType descriptors


byte 3 (*)byte 2byte 1 (*)byte 0
EEI Quadrupoles DC01010007
EEI Dipoles DC02010007
EEI Dipole pseudo-pulsed03000007
CAENels NGPS (new UFS).........08

Pattern for EEI

byte 3      01 = Type quadrupole DC, 02 = Type dipole DC, 03 = Type dipole pseudo-pulsed
byte 2      00 = bipolar, 01 = unipolar with remote control of polarity change
byte 1       xx = interface type (unique in this case ?) TO BE DECIDED: maybe the pseudo-pulsed should be different
byte 0      07 = Protocol EEI

Pattern for CAENels NGPS

byte 3      xx = TO BE DECIDED
byte 2      xx = TO BE DECIDED
byte 1       xx = TO BE DECIDED
byte 0      08 = Protocol CAENels NGPS

How to search for a specific

...

elemType in all

...

DBSta files

Code Block
languagetext
titleExample of DBFile for an element of class "MG1"
%MG1

...


#DHSA*001

...


@HCI(S)[(I32),(DBL),HU32,DBL,DBL,DBL,DBL,DI32,DBL:2:4]

...


MG1,DHSA*001,00020000,0.1,3.0,3.0,3.0,1,11.0:12.0:13.0:14.0:21.0:22.0:23.0:24.0

...


... etc

...

 ...
             XXXXXX00
			       --

The first byte of the elementType field, indicates the PS protocol

...

(e.g. in the above example, "00" indicates the protocol SYS8X00

...

).

Using the egrep command

Code Block
languagetext
egrep "^MG1,.{8},[0-9]{6}00," ./DEVIL6??.DBSta

...



^MG1		matches "MG1" at the beginning of a line

...


,

...

			matches

...

 ","

...


.{8}

...

		matches any sequence of 8 characters (e.g. DHSA*001)

...


,

...

			matches

...

 ","

...


[0-9]{6}00

...

	matches any sequence of 6 digits followed by "00" (e.g. 00020000)

...


,

...

			matches ","

Example of search: an OCEM PS that can switch has the elemType:

XX01XX01

grep [0-9][0-9]01[0-9][0-9]01 ./DEVIL6??.DBSta
or
egrep "^MG1,.{8},[0-9]{2}01[0-9]{2}01," ./DEVIL6??.DBSta

maxCmdExeTime

maxCmdExeTime#0

SETT (* ∆I)

STRG (* ∆I)

maxCmdExeTime#1

RESE


maxCmdExeTime#2

POWR

MODE (STBY->OPER)

POLA

WAVE
SWTC

maxCmdExeTime#3

MODE for EEI (OPER->STBY)

...