Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

In this page you can find all network switches connection and inside section's pages you can find all port configuration.

SWBTFCR2Cisco 2960-X 48pSFP1Disconnected (SPARE)SWFINUDAGECisco 3550 10gbicGBIC131a-28B-PC1-4A,4B →
CALCOLO
GBIC5

31a-28B-SWFINUDASALA-GBIC1

GBIC6

31a-28B-SWFINUDASALA-GBIC2

GBIC7

31a-021HM-SWFINUDASALA2-SFP1

GBIC8

31a-021HM-SWFINUDASALA2-SFP2

GBIC9

31a-28B-SWBTFCRNEW-SFP2

GBIC10Connected Fiber but port offlineSWFINUDASALACisco 3550 48pGBIC1

31a-28B-SWFINUDAGE-GBIC5

GBIC231a-28B-SWFINUDAGE-GBIC6Rack 021HMSWFINUDASALA2Cisco 2960G 20p + 4sfpSFP1

31a-28B-SWFINUDAGE-GBIC7

SFP231a-28B-SWFINUDAGE-GBIC8Nuova Sala Sperimentale BTF19Rack 006SWBTFCisco 3550 48pGBIC119-006-PC1-1,2 →
41-028-PC1-1,2 →
41-028-SWLAT-MOD5-1SWBTF3Cisco 2960-X 48pSFP119-006-PC1-19,20 →
41-028-PC4-4A,4B →
41-028-SWLAT-MOD4-12SFP219-006-PC1-17,18 →
41-028-PC4-3A,3B →
41-028-SWLAT-MOD4-11
Room NameRoom NumberPositionSwitch NameSwitch ModelPortConnected to
Nuova Sala Controllo BTF31a
Rack 28BSWBTFCRNEWCisco 2960-X 48pSFP2

31a-28B-SWFINUDAGE-GBIC9

Sala Alimentatori Accumulatore21Rack 018SWACC1Cisco 2960-X 48pSFP221-018-PC1-1A,1B →
19-006-PC3-7A,7B →
19-006-PC1-3,4 →
41-028-PC1-3,4 →
41-028-SWLAT-MOD5-2
Sala Alimentatori Dafne (o Sala Conteggio)43Rack 074
SWALIMDAFNE
SWALIMDAFNE1Cisco 2960-X 48pSFP143-074-PC1-1A,1B →
41-028-PC3-1,2 →
41-028-SWLAT-MOD5-8
ETH4543-082-UNMANAGED-24
ETH4643-078-UNMANAGED-24
ETH4743-076-UNMANAGED-24
ETH4843-067-UNMANAGED-16
Rack 082UnmanagedHP OfficeConnect 1420 24pETH2443-074-
SWALIMDAFNE
SWALIMDAFNE1-45
Rack 078UnmanagedHP OfficeConnect 1420 24pETH2443-074-
SWALIMDAFNE
SWALIMDAFNE1-46
Rack 076UnmanagedHP OfficeConnect 1420 24pETH2443-074-
SWALIMDAFNE
SWALIMDAFNE1-47
Rack 067UnmanagedHP OfficeConnect 1420 16pETH1643-074-
SWALIMDAFNE
SWALIMDAFNE1-48
Sala Controllo
DAFNE32Rack 002SWCTRL1Cisco 2960 24pSFP142-030-PC5-1A,1B
BTF31aRack 28BSWBTFCR1Cisco 2960-X 48pSFP131a-28B-PC3-2 →
41-028-PC6-2 →
41-028-SWLAT-MOD2-12
Rack 021HMSWBTFCR3Cisco 2960-X 48pSFP131a-28B-PC3-1
41-028-
PC2
PC6-
13,14
1
41-028-SWLAT
-MOD5-9SFP232-T1-SWCTRL2-SFP1
-MOD2-11
Sala Controllo DAFNE32Rack 002SWDAFNECR1
Cisco 2960-X 48p
SFP1

32-005-PC2-2A,2B →
41-028-PC3-15,16 →
41-028-SWLAT-MOD4-11


Table 1
SWCTRL2
SWDAFNECR2Cisco 2960-X 48pSFP132
-002-SWCTRL1-SFP2
-005-PC2-3A,3B →
41-028-PC3-17,18 →
41-028-SWLAT-MOD4-12
Rack 005UnmanagedHP OfficeConnect 1420 24pSFP132-005-PC2-1A,1B →
41-028-PC3-13,14 →
41-028-SWLAT-MOD5-11
Sala Criogenia10Rack 000
SWCRIO
SWCRIO1Cisco
3550
2960-X 48p
GBIC1
SFP110-000-PC1-1,2 →
41-028-PC1-13,14 →
41-028-SWLAT-MOD5-5
Sala Dafne















11















Rack 064
SWDAFNE4B
SWDAFNEH4Cisco 2960-X 48pSFP211-064-PC1-1A,1B →
11-065-PC5-1,2 →
11-065-PC2-11,12 →
41-028-PC2-11,12 →
41-028-SWLAT-MOD4-7
Rack 065
SWDAFNE1
SWDAFNEH1Cisco 2960-X 48pSFP111-065-PC1-1,2 →
41-028-PC1-17,18 →
41-028-SWLAT-MOD5-6
ETH1911-I23-UNMANAGED-16
ETH2011-I28-UNMANAGED-16
Rack 069
SWDAFNE2C
SWDAFNEH2Cisco 2960-X 48pSFP211-069-PC2-7A,7B →
11-065-PC5-13,14 →
11-065-PC2-7,8 →
41-028-PC2-7,8 →
41-028-SWLAT-MOD4-17
ETH1911-I3-UNMANAGED-24
ETH2011-I9-UNMANAGED-24
Rack 072
SWDAFNE3B
SWDAFNEH3Cisco 2960-X 48pSFP111-072-PC1-1A,1B →
11-065-PC4-1,2 →
11-065-PC2-9,10 →
41-028-PC2-9,10 →
41-028-SWLAT-MOD4-18
Rack SIDSWSIDDHARTA10G???SFP?11-SID-SWSIDDHARTA-SFP?
SWSIDDHARTA???SFP?11-SID-SWSIDDHARTA10G-SFP?
SFP?11-064-PC1-4A,4B →
11-065-PC5-7,8 →
11-065-PC2-5,6 →
41-028-PC2-5,6 →
41-028-SWLAT-MOD4-16
Rack BUCA SXSWLUMIGIB???SFP?11-064-PC1-3A,3B →
11-065-PC5-5,6 →
11-065-PC2-3,4 →
41-028-PC2-3,4 →
41-028-SWLAT-MOD4-15
Rack BUCA DXSWLUMICHAOS???SFP?11-064-PC1-2A,2B →
11-065-PC5-3,4 →
11-065-PC2-1,2 →
41-028-PC2-1,2 →
41-028-SWLAT-MOD4-14
Rack Inverpower 3UnmanagedHP Procurve 2124 J4868A 24pETH2411-069-
SWDAFNE2C
SWDAFNEH2-19
Rack Inverpower 9UnmanagedHP Procurve 2124 J4868A 24pETH2411-069-
SWDAFNE2C
SWDAFNEH2-20
Rack Inverpower 23UnmanagedHP 1410-16G J9560A 16pETH1611-065-
SWDAFNE1
SWDAFNEH1-19
Rack Inverpower 28UnmanagedHP 1410-16G J9560A 16pETH1611-065-
SWDAFNE1
SWDAFNEH1-20
Sala LAT41Rack 028SWLATCisco 4506-E 48p + 36sfpMOD2-741-028-PC7-10
18-PADME-1
18-017-SWBTFEH11-SFP1
MOD2-841-028-PC7-11
18-PADME-2
19-006-SWBTFEH21-SFP1
MOD2-941-028-PC7-12
18-PADME-3
19-006-SWBTFEH22-SFP1
MOD2-1041-028-PC7-13
18-PADME-4
19-MOBILE-SWBTFEH23-SFP1
MOD2-1141-028-PC6-1
31a-28B-PC3-1
31a-28B-SWBTFCR3-SFP1
MOD2-1241-028-PC6-2 →
31a-28B-PC3-2 →
31a-021HM-SWBTFCR1-SFP1
MOD4-741-028-PC2-11,12 →
11-065-PC2-11,12 →
11-065-PC5-1,2 →
11-064-PC1-1A,1B →
11-064-
SWDAFNE4B
SWDAFNEH4-SFP2
MOD4-841-028-PC1-7,8 →
03-015-PC1-3,4 →
03-PLMG-SWMOD2-
GBIC1
SFP1
MOD4-941-028-PC1-23,24 →
42-031-PC2-3,4 →
42-031-SWSTRUM1-SFP1
MOD4-1041-028-PC2-15,16 →
42-030-PC5-2A,2B →
42-030-SWSTRUM2-SFP1
MOD4-11

41-028-

PC4

PC3-

3A

15,

3B →

16 →

19

32-

006

005-

PC1

PC2-

17

2A,

18

2B

19

32-

006

002-

SWBTF3

SWDAFNECR1-

SFP2

SFP1

MOD4-1241-028-
PC4
PC3-
4A
17,
4B →
18 →
19
32-
006
005-
PC1
PC2-
19
3A,
20
3B
19
32-
006
T1-
SWBTF3
SWDAFNECR2-SFP1
MOD4-1341-028-PC2-17,18 →
42-030-PC5-3A,3B →
42-031-PC2-7,8 →
03-015-PC1-7,8 →
03-PLMG-SWMOD3-SFP2
MOD4-1441-028-PC2-1,2 →
11-065-PC2-1,2 →
11-065-PC5-3,4 →
11-064-PC1-2A,2B →
11-BUCA_DX-SWLUMICHAOS-SFP?
MOD4-1541-028-PC2-3,4 →
11-065-PC2-3,4 →
11-065-PC5-5,6 →
11-064-PC1-3A,3B →
11-BUCA_SX-SWLUMIGIB-SFP?
MOD4-1641-028-PC2-5,6 →
11-065-PC2-5,6 →
11-065-PC5-7,8 →
11-064-PC1-4A,4B →
11-SID-SWSIDDHARTA-SFP?
11-SID-SWSIDDHARTA10G-SFP?
MOD4-1741-028-PC2-7,8 →
11-065-PC2-7,8 →
11-065-PC5-13,14 →
11-069-PC2-7A,7B →
11-069-
SWDAFNE2C
SWDAFNEH2-SFP2
MOD4-1841-028-PC2-9,10 →
11-065-PC2-9,10 →
11-065-PC4-1,2 →
11-072-PC1-1A,1B →
11-072-
SWDAFNE3B
SWDAFNEH3-SFP1
MOD5-
141-028-PC1-1,2 →
19-006-PC1-1,
2
19-006-SWBTF-GBIC1MOD5-2
41-028-PC1-3,4 →
19-006-PC1-3,4 →
19-006-PC3-7A,7B →
21-018-PC1-1A,1B →
21-018-SWACC1-SFP2
MOD5-341-028-PC1-5,6 →
03-015-PC1-1,2 →
03-015-SWMOD1-
GBIC1
SFP1
MOD5-441-028-PC1-9,10 →
8b-073-PC1-1,2 →
8b-073-
SWMACC
SWMAC1-
GBIC1
SFP1
MOD5-541-028-PC1-13,14 →
10-000-PC1-1,2 →
10-000-
SWCRIO
SWCRIO1-
GBIC1
SFP1
MOD5-641-028-PC1-17,18 →
11-065-PC1-1,2 →
11-065-
SWDAFNE1MOD5-941-028-PC2-13,14 →
42-030-PC5-1A,1B →
32-002-SWCTRL1-SFP1 →
32-T1-SWCTRL2-SFP1MOD5-1041-028-PC4-1A,1B →
19-006-PC1-13,14 →
19-006-PC3-1A,1B →
18-017-PC1-1A,1B →
18-017-SWBTFESP1-SFP2
18-017-SWBTFESP2-GBIC1
SWDAFNEH1-SFP1
MOD5-741-028-PC1-21,22 →
42-031-PC2-1,2 →
42-031-SWSTRUM3-SFP1
MOD5-841-028-PC3-1,2 →
43-074-PC1-1A,1B →
43-074-
SWALIMDAFNE-SFP1
SWALIMDAFNE1-SFP1
MOD5-1141-028-PC3-13,14 →
32-005-PC2-1A,1B →
32-005-UNMANAGED-SFP1
MOD5-1241-028-SWLAT2-SFP1
SWLAT2Cisco 2960-X 48pSFP141-028-SWLAT-MOD5-12
Sala Macchine8bRack 073
SWMACC
SWMAC1Cisco
3550 24pGBIC1
2960-X 48p
SFP18b-073-PC1-1,2 →
41-028-PC1-9,10 →
41-028-SWLAT-MOD5-4
Sala Modulatori03Rack 015SWMOD1Cisco
3550 24pGBIC1
2960-X 48p
SFP103-015-PC1-1,2 →
41-028-PC1-5,6 →
41-028-SWLAT-MOD5-3
Rack PLMGSWMOD2Cisco
3550 24pGBIC1
2960-X 48p
SFP103-015-PC1-3,4 →
41-028-PC1-7,8 →
41-028-SWLAT-MOD4-8
SWMOD3Cisco 2960-X 48pSFP203-015-PC1-7,8 →
42-031-PC2-7,8 →
42-030-PC5-3A,3B →
41-028-PC2-17,18 →
41-028-SWLAT-MOD4-13
Sala Sperimentale BTF 118Rack 017
SWBTFESP1SFP218-017-PC1-1A,1B →
19-006-PC3-1A,1B →
19-006-PC1-13,14
SWBTFEH11Cisco 2960-X 48pSFP118
-017-SWBTFESP2-GBIC1
-PADME-1
41-028-PC7-10
41-028-SWLAT-MOD2-7
Sala Sperimentale BTF 219Rack 006SWBTFEH21Cisco 2960-X 48pSFP118-PADME-2
41-028-PC7-11
41-028-SWLAT-MOD2-8
SWBTFEH22Cisco 2960-X 48pSFP118-PADME-3

41-028-
PC4
PC7-
1A,1B
12
41-028-SWLAT-
MOD5-10SWBTFESP2Cisco 3550 24pGBIC118-017-SWBTFESP1-SFP1
MOD2-9
Rack MobileSWBTFEH23Cisco 2960-X 48pSFP118-PADME-4
41-028-PC7-13
41-028-SWLAT-MOD2-10
Sala Strumentazione42Rack 030SWSTRUM2Cisco 2960-X 48pSFP142-030-PC5-2A,2B →
41-028-PC2-15,16 →
41-028-SWLAT-MOD4-10
Rack 031SWSTRUM1Cisco 2960-X 48pSFP142-031-PC2-3,4 →
41-028-PC1-23,24 →
41-028-SWLAT-MOD4-9
SWSTRUM3Cisco 2960-X 48pSFP142-031-PC2-1,2 →
41-028-PC1-21,22 →
41-028-SWLAT-MOD5-7